DISCONTINUED: The 3045 Dissolved Copper Analyzer is replaced by the 3145 Dissolved Copper Analyzer
3045 Dissolved Copper Analyzer
Range: 0–100ppb
Range: 0–3ppm
The Waltron 3045 Dissolved Copper Analyzer is the most reliable instrument for online colorimetric measurement of dissolved copper in clean water applications. Online dissolved copper analysis is increasingly critical as an effective method to monitor corrosion within specialty steam and boiler water systems. An enhanced color touchscreen user interface makes the 3045 easy to operate and configure, and the clever fast-loop reservoir feature allows accurate measurement independent of flow. The 3045 alone can deliver the most accurate and precise results for ultra-pure water applications.
- Accurate and wide-range analysis
- Multi-stream available
- Fast loop reservoir
- Adjustable cycle and calibration frequency
- Automatic calibration and validation (QA/QC)
- Compact design
- Color touchscreen display
- Grab sample capability
- Internal datalogger
- Low reagent level alarm
- No compressed air is required
- Automatic start/stop based on sample flow detection
- Minimal analyzer maintenance
PERFORMANCE
Range
0–100 ppb, 0–3 ppm
Accuracy
+/– 2% of full scale
Reproducibility
+/– 2% of reading
Analysis Time
10 min, batch process
Sampling Frequency (Cycle Time)
One reading every 15 mins, adjustable
Sensor Classification
Colorimetric with glass flowcell and LED source
Power Supply
110-220Vac, 50-60 Hz 80 VA
Humidity
Up to 90% not condensable
Ambient Temperature Range
5-55°C analyzer (41-131°F)
Dimensions
Height = 26” (66.1cm), Width = 15” (38.1cm) Depth = 12” (30.5 cm)
Positioning and Installation Details
Wall mounting, bench supported, or panel mounting (optional)
Alarms
2 or 4 configurable alarm relays
Degree of Protection
IP55 (NEMA 4): Wet section, IP65 (NEMA 4x): Electronics
Required Maintenance
Once a month replenish reagents, Quarterly replace tubing
Reagent Consumption (approximate)
3 reagents, 2L each per month
Materials in Contact with Sample
Glass, Silicone, Plexiglass, Stainless Steel AISI 316
Certification (on request):
Meets low voltage and low electromagnetic compatibility directives
Sample Conditioning Requirements
Filtering between 10 and 60 micron, depending on the matrix, needed only to avoid clogging.
Weight
17 kg (37.5 lbs.)
SAMPLE DELIVERY OPERATING CONDITIONS
Temperature Range
5-55º C (41-131º F)
Inlet Sample
100–500 ml/min, atmospheric, flexible tubing O.D. 1/4″ (6 mm)
Outlet Sample
Atmospheric, waste tubing O.D. 3/8 (9 mm)
PH
3-12
SIGNAL OUTPUTS
Analog Outputs
4-20mA (galvanic isolator module available as option) or 0-5V
Serial I/O for Signals
RS232, RS485; MODBUS; PROFIBUS
OPERATIONAL CALIBRATION
Frequency/Intervals
Recommended: 7 days
Single/Multi-Point
Multi-Point: zero and mid-range
Manual/Automatic
Both