Waltron 3042 Phosphate Analyzer

3042 Phosphate Analyzer

Range: 0 – 5 ppm

Range: 0 – 20 ppm

Range: 0 – 150 ppm

Range: 0 – 300 ppm


Waltron’s 3042 Phosphate Analyzer is the first choice for online analysis of dissolved phosphate in ultrapure water applications. The 3042 is trusted worldwide to deliver accurate and reliable readings with minimal maintenance and a low total cost of ownership. Common application points in a boiler system include make-up water, condensate, boiler feedwater, saturated steam/main steam, and cooling water.

  • Accurate and wide-range analysis

  • Multi-stream available

  • Fast loop reservoir

  • Adjustable cycle and calibration frequency

  • Automatic calibration and validation (QA/QC)

  • Compact design

  • Color touchscreen display

  • Grab sample capability

  • Internal datalogger

  • Low reagent level alarm

  • No compressed air is required

  • Automatic start/stop based on sample flow detection

  • Minimal analyzer maintenance

PERFORMANCE


Range

0–5 ppm, 0–20 ppm, 0-150 ppm, 0-300 ppm


Accuracy

+/– 2% of full scale


Reproducibility

+/– 2% of reading


Analysis Time

9 min. batch process


Sampling Frequency (Cycle Time)

One reading every 15 mins, adjustable


Sensor Classification

Colorimetric with glass flowcell and LED source


Power Supply

110-220Vac, 50-60 Hz 80 VA


Humidity

Up to 90% not condensable


Ambient Temperature Range

5-55°C analyzer (41-131°F)


Positioning and Installation Details

Wall mounting, bench-supported, or panel mounting (optional)


Alarms

2 or 4 configurable alarm relays


Degree of Protection

IP55 (NEMA 4): Wet section, IP65 (NEMA 4x): Electronics


Required Maintenance

Once a month, replenish reagents; Quarterly replace tubing


Reagent Consumption (approximate)

Reagent consumption: 1 or 2 reagents (depending on range), 2L per month.


Materials in Contact with Sample

Glass, Silicone, Plexiglass, Stainless Steel AISI 316


Certification (on request):

Meets low voltage and low electromagnetic compatibility directives


Sample Conditioning Requirements

Filtering between 10 and 60 microns, depending on the matrix, is needed only to avoid clogging.


Weight

17 kg (37.5 lbs.)

SAMPLE DELIVERY OPERATING CONDITIONS


Temperature Range

5-55º C (41-131º F)


Inlet Sample

100–500 ml/min, atmospheric, flexible tubing O.D. 1/4″ (6 mm)


Outlet Sample

Atmospheric, waste tubing O.D. 3/8 (9 mm)


PH

3-12

SIGNAL OUTPUTS


Analog Outputs

4-20mA (galvanic isolator module available as an option) or 0-5V


Serial I/O for Signals

RS232, RS485; MODBUS; PROFIBUS

OPERATIONAL CALIBRATION


Frequency/Intervals

Recommended: 7 days


Single/Multi-Point

Multi-Point: zero and mid-range


Manual/Automatic

Both