9095 MultiCon Analyzer
Range: 0-9.999µS/cm
Range: 0-99.9µS/cm
The Waltron 9095 Multi-Conductivity Analyzer continuously measures conductivity before and after cation exchange, while automatically calculating the pH value of the sample and alkalizing reagent concentration of feed-water, steam, and condensate. An enhanced color touchscreen user interface makes the 9095 easy and intuitive to operate and configure. This combination-measurement technology saves panel space and delivers the most accurate specific and cation conductivity measurements with simple maintenance and consumables.
- Highly accurate calculated pH
- Alarm for cation resin exhaustion
- Easy to replace cation column
- Easy to mount stainless steel panel
- One transmitter for two conductivity values and pH
- Dual channel option (9094C)
PERFORMANCE
Range
0-10µS/cm, 0-100µS/cm
Accuracy
< 0.6% of the measuring range
Reagent Consumption (approximate)
Cation Resin (pre-rinsed); replace cartridge every two months
Sensor Classification
Cationic exchange and conductivity sensors
Data Storage
Extract via USB 2.0 (optional)
Power Supply
AC 110 to 240 V +10 / -15%; 48 to 63 Hz or AC/DC 20 to 30 V; 48 t0 63 Hz
OPERATING CONDITIONS
Sample Temperature Range
32 – 122° F (0 – 50 °C)
Ambient Temperature Range
32 – 140° F (0 – 60 °C)
Inlet Sample Flowrate
.031 – .044 GPM (7-10L/h), 6mm Swagelok
Inlet Sample Pressure
Maximum of 145 psig (10 bar)
Outlet Sample
Atmospheric
SIGNAL OUTPUTS
Analog Outputs
5 x 0/4 – 20 mA for measured signals
Alarms
General Alarm, Resin Exhausted Alarm
Optional
RS422/RS485
MECHANICAL
Construction
Transmitter – high strength ABS, IP67
Wet section – stainless steel or PVC
Dimensions
14.5 x 33.5 x 10″ (368 x 851 x 254mm)
Mounting
Wall mount or Panel mount
Finish
Corrosion resistant