Waltron 3046 Ammonia Analyzer

3046 Ammonia Analyzer

Range: 0–1000ppb


Waltron’s 3046 Ammonia Analyzer is specifically designed for the online analysis of ammonia as used for pH control in high purity process water. The 3046 is a member of the Waltron 3040 Series of colorimetric analyzers. The 3040 Series is trusted world wide to deliver accurate and reliable readings with minimal maintenance and low total cost of ownership. Common applications include boiler cycle water and condensate return systems.

  • Accurate and wide-range analysis

  • Multi-stream available

  • Fast loop reservoir

  • Adjustable cycle and calibration frequency

  • Automatic calibration and validation (QA/QC)

  • Compact design

  • Color touchscreen display

  • Grab sample capability

  • Internal datalogger

  • Low reagent level alarm

  • No compressed air required

  • Automatic start/stop based on sample flow detection

  • Minimal analyzer maintenance

  • Automatic chemical cleaning integrated

PERFORMANCE


Range

0–1000ppb, 0–3000ppb


Accuracy

+/– 5 ppb or +/– 2% of reading, whichever is greater


Reproducibility

+/– 5 ppb or +/– 2% of reading, whichever is greater


Analysis Time

15 min, batch process


Sampling Frequency (Cycle Time)

One reading every 20 mins, adjustable


Required Maintenance

Monthly replenish reagents; Quarterly replace tubing


Reagent Consumption (approximate)

3 reagents, 2.5L each per month, optional 4th reagent as cleaning solution


Sensor Classification

Colorimetric with glass flowcell and LED source


Application

Steam cycle water, cooling water, process water


Ambient Temperature Range

5-55°C analyzer (41-131°F)


Atmospheric Pressure Range

No Limits


Humidity

Up to 90% not condensable


Unit Dimensions

Height=23.6”(60 cm), Width=15”(38 cm), Depth=8.3”(21 cm)


Positioning and Installation Details

Wall mounting, bench-supported, or panel mounting (optional)


Weight

17 kg (37.5 lbs.)


Degree of Protection

IP55 (NEMA 4): Wet section, IP65 (NEMA 4x): Electronics


Alarms

2 or 4 configurable alarm relays (Result, loss of sample, fault)


Power Supply

110-220Vac, 50-60 Hz 80 VA


Certification (on request):

Meets low voltage and low electromagnetic compatibility directives


SAMPLE DELIVERY OPERATING CONDITIONS


Temperature Range

5-55º C (41-131º F)


Inlet Sample

100–500 ml/min, atmospheric, flexible tubing O.D. 1/4″ (6 mm)


Outlet Sample

Atmospheric, waste tubing O.D. 3/8 (9 mm)


PH

3-12


Sample Conditioning Requirements

Filtering between 10 and 60 micron, depending on the matrix, needed only to avoid clogging


Materials in Contact with Sample

Glass, Silicone, Plexiglass, Stainless Steel AISI 316

SIGNAL OUTPUTS


Analog Outputs

4-20mA (galvanic isolator module available as option) or 0-5V


Serial I/O for Signals

RS232, RS485; MODBUS; PROFIBUS

OPERATIONAL CALIBRATION


Single/Multi-Point

Multi-Point: zero and mid-range


Manual/Automatic

Both


Technical Documents