3054 Filming Amines Analyzer
Range: 0-500ppb
The Waltron 3054 Filming Amines Analyzer is the first analyzer explicitly developed to analyze film-forming amine products in clean water applications online. The 3054 is the latest addition to the Waltron 3040 Series of colorimetric analyzers, trusted worldwide to deliver accurate and reliable readings with minimal maintenance and a low total cost of ownership. An enhanced color touchscreen user interface makes the 3054 easy to operate and configure, and the clever fast-loop reservoir feature allows accurate measurement independent of flow. Waltron has collaborated with several major chemical companies to fine-tune the instrument to report residual concentrations of a growing list of film-forming amine products using its proprietary reagent technology. Typical applications are boiler cycle water and process water.
- Accurate and wide-range analysis
- Multi-stream available
- Fast loop reservoir
- Adjustable cycle and calibration frequency
- Automatic calibration and validation (QA/QC)
- Compact design
- Color touchscreen display
- Grab sample capability
- Internal datalogger
- Low reagent level alarm
- No compressed air required
- Automatic start/stop based on sample flow detection
- Minimal analyzer maintenance
- Automatic chemical cleaning integrated
PERFORMANCE
Range
0–500 ppb
Accuracy and Repeatability
+/- 10 PPB or +/- 5% of reading whichever is greater
Analysis Time
9 min, batch process
Sampling Frequency (Cycle Time)
One reading every 20 mins, adjustable
Required Maintenance
Monthly replenish reagents; Quarterly replace tubing
Reagent Consumption (approximate)
3 reagents, 2.5L each per month
Sensor Classification
Colorimetric with glass flowcell and LED source
Application
Steam cycle water, cooling water, process water
Ambient Temperature Range
5-55°C analyzer (41-131°F)
Atmospheric Pressure Range
No Limits
Humidity
Up to 90% not condensable
Unit Dimensions
Height = 26” (66.1cm), Width = 15” (38.1cm) Depth = 12” (30.5 cm)
Positioning and Installation Details
Wall mounting, bench-supported, or panel mounting (optional)
Weight
17 kg (37.5 lbs.)
Degree of Protection
IP55 (NEMA 4): Wet section, IP65 (NEMA 4x): Electronics
Alarms
2 or 4 configurable alarm relays (Result, loss of sample, fault)
Power Supply
110-220Vac, 50-60 Hz 80 VA
Certification (on request):
Meets low voltage and low electromagnetic compatibility directives
SAMPLE DELIVERY OPERATING CONDITIONS
Temperature Range
5-55º C (41-131º F)
Inlet Sample
100–500 ml/min, atmospheric, flexible tubing O.D. 1/4″ (6 mm)
Outlet Sample
Atmospheric, waste tubing O.D. 3/8 (9 mm)
PH
3-12
Sample Conditioning Requirements
Filtering between 10 and 60 microns, depending on the matrix, is needed only to avoid clogging
Materials in Contact with Sample
Glass, Silicone, Plexiglass, Stainless Steel AISI 316
SIGNAL OUTPUTS
Analog Outputs
4-20mA (galvanic isolator module available as an option) or 0-5V
Serial I/O for Signals
RS232, RS485; MODBUS; PROFIBUS
OPERATIONAL CALIBRATION
Single/Multi-Point
Multi-Point: zero and mid-range
Matrix Corrections
Yes, sample blank correction
Manual/Automatic
Both