3054 Filming Amines Analyzer

DISCONTINUED: The 3054 Filming Amines Analyzer is replaced by the updated 3154 Filming Amines Analyzer.


3054 Filming Amines Analyzer

Range: 0-500ppb


The Waltron 3054 Filming Amines Analyzer is the first analyzer explicitly developed to analyze film-forming amine products in clean water applications online. The 3054 is the latest addition to the Waltron 3040 Series of colorimetric analyzers, trusted worldwide to deliver accurate and reliable readings with minimal maintenance and a low total cost of ownership. An enhanced color touchscreen user interface makes the 3054 easy to operate and configure, and the clever fast-loop reservoir feature allows accurate measurement independent of flow. Waltron has collaborated with several major chemical companies to fine-tune the instrument to report residual concentrations of a growing list of film-forming amine products using its proprietary reagent technology. Typical applications are boiler cycle water and process water.

  • Accurate and wide-range analysis

  • Multi-stream available

  • Fast loop reservoir

  • Adjustable cycle and calibration frequency

  • Automatic calibration and validation (QA/QC)

  • Compact design

  • Color touchscreen display

  • Grab sample capability

  • Internal datalogger

  • Low reagent level alarm

  • No compressed air required

  • Automatic start/stop based on sample flow detection

  • Minimal analyzer maintenance

  • Automatic chemical cleaning integrated

PERFORMANCE


Range

0–500 ppb


Accuracy and Repeatability

+/- 10 PPB or +/- 5% of reading whichever is greater


Analysis Time

9 min, batch process


Sampling Frequency (Cycle Time)

One reading every 20 mins, adjustable


Required Maintenance

Monthly replenish reagents; Quarterly replace tubing


Reagent Consumption (approximate)

3 reagents, 2.5L each per month


Sensor Classification

Colorimetric with glass flowcell and LED source


Application

Steam cycle water, cooling water, process water


Ambient Temperature Range

5-55°C analyzer (41-131°F)


Atmospheric Pressure Range

No Limits


Humidity

Up to 90% not condensable


Unit Dimensions

Height = 26” (66.1cm), Width = 15” (38.1cm) Depth = 12” (30.5 cm)


Positioning and Installation Details

Wall mounting, bench-supported, or panel mounting (optional)


Weight

17 kg (37.5 lbs.)


Degree of Protection

IP55 (NEMA 4): Wet section, IP65 (NEMA 4x): Electronics


Alarms

2 or 4 configurable alarm relays (Result, loss of sample, fault)


Power Supply

110-220Vac, 50-60 Hz 80 VA


Certification (on request):

Meets low voltage and low electromagnetic compatibility directives


SAMPLE DELIVERY OPERATING CONDITIONS


Temperature Range

5-55º C (41-131º F)


Inlet Sample

100–500 ml/min, atmospheric, flexible tubing O.D. 1/4″ (6 mm)


Outlet Sample

Atmospheric, waste tubing O.D. 3/8 (9 mm)


PH

3-12


Sample Conditioning Requirements

Filtering between 10 and 60 microns, depending on the matrix, is needed only to avoid clogging


Materials in Contact with Sample

Glass, Silicone, Plexiglass, Stainless Steel AISI 316

SIGNAL OUTPUTS

Analog Outputs

4-20mA (galvanic isolator module available as an option) or 0-5V


Serial I/O for Signals

RS232, RS485; MODBUS; PROFIBUS

OPERATIONAL CALIBRATION


Single/Multi-Point

Multi-Point: zero and mid-range


Matrix Corrections

Yes, sample blank correction


Manual/Automatic

Both


Technical Documents