4000-Series-Transmitter-1024x1024-1

4000 EC Electrodeless Conductivity Analyzer

0-999.9pS/cm,0-9.999mS/cm
0-99.99ms/cm, 0-999.9mS/cm
0-999.9 ppm, 0-9999 ppm
0-99.99 ppt (parts per thousand)

Solution concentration: Defined by a user entered 2 to 9 point curve. User defined scale: 0 to 999.9, 0 to 99.99, 0 to 999.9, and 0 to 9999. User defined units up to 5 characters.


Streamline Water Monitoring with Waltron’s All-New Contactless Conductivity Analyzer

Meet the Waltron 4000 EC Electrodeless Conductivity Analyzer, a solid choice for high-range conductivity measurements. The Waltron 4000 EC stands out with its robust features, such as a broad spectrum of measurement ranges, user-defined solution concentration curves, and various user-defined units.

KEY FEATURES


  • Single-Channel Electrodeless Conductivity for use with a wide range of inductive sensors

  • Able to simultaneously display conductivity, % solution concentration, and temperature

  • Easy to install and configure with two relays, two digital inputs, and two 4-20mA outputs

  • Durable 1/2-DIN IP66 NEMA 4X enclosure can be panel, surface, or pipe-mounted

  • Simple, intuitive menu, with soft-touch buttons and a large, clear LCD backlit display

  • User adjustable temperature slope

  • Choice of 12-30VDC or 90-265VAC versions

PERFORMANCE


Display

3.75″, 240 x 128 dot, LCD module


Display backlight

Can be set to flash to indicate the instruments alarm status


Languages

English, French, Spanish, and Italian


Buttons

5, silicone rubber tactile feedback micro-switched


Digital inputs

2 contact inputs for remote activation of user-defined operations. It can be configured to operate in either normally open or normally closed modes.


Current output specification

Single current output, selectable 0-20mA or 4-20mA into 750 ohms max, fully isolated to 2kV. Expandable across the full operating range and offset anywhere in that range. Loop fault detection.


Setpoints and control relays specification

2 normally open fully configurable setpoints with volt-free contacts for each relay. Rated at 5A @ 30vDC / 5A @ 250vAC.


MicroSD card interface

Enables on-site upgrading of instrument software. SD, SDHC and SDXC-FAT32 cards supported.


Measurement input

ECS20 or ECS40 series electrodeless (inductive) conductivity sensor.


Connection cable

Up to 30 metres


Measurement ranges

0-999.9pS/cm,0-9.999mS/cm

0-99.99ms/cm, 0-999.9mS/cm

0-999.9 ppm, 0-9999 ppm

0-99.99 ppt (parts per thousand)

Solution concentration: Defined by a user entered 2 to 9 point curve. User defined scale: 0 to 999.9, 0 to 99.99, 0 to 999.9, and 0 to 9999. User defined units up to 5 characters.


Range selection

Internal single or auto range.


Conductivity accuracy

± 1 % of range.


Linearity and Repeatability

± 0.1% of range.


Operator adjustment (conductivity)

Conductivity ± 10% slope.

Solution ± 20% offset.


Temperature compensation type

Automatic or manual, variable slope 0 – 9.99 %/°C


Temperature compensation base

Selectable at 20 °C or 25 °C.


Additional setpoint modes

Proportional (Setpoint 2 only) The setpoint will dose in proportion to the time that setpoint 1 was on. e.g. If setpoint is energised for 10 minutes and the proportion is set to 50% then setpoint 2 will start dosing for 5 minutes immediately after setpoint 1 has de-energised. Accumulation (Setpoint 2 only) The setpoint will dose for the set dose time after the accumulation active time of setpoint 1 has been reached.

OPERATING CONDITIONS


Ambient operating conditions

Temperature -20 to +55°C, relative humidity 5 to 95%. non-condensing.


Power supply

Universal 90-265vAC, 10W max.
LV Option 12-30vDC, 5W max.

MECHANICAL


Instrument housing

UL 94-VO PC/ABS
Front panel 144 x 144mm (Panel-cut out: 138 x 138mm) Depth behind panel: 77mm maximum
Hinged / retained front


Ingress protection rating (IEC 60529 protection rating)
IP66

Technical Documents

  • Coming Soon!

PERFORMANCE


Range

0 to 9 999 uS/cm, 0 to 99.99 uS/cm


Accuracy

< 0.6% of the measuring range


Degassing Efficiency

93.5% in less than 90 seconds


User Interface

5.5” color touch screen


Alarms

General Alarm, Low Degassing Efficiency Alarm, Resin Exhausted Alarm


Analog Outputs

4 x 0/4 – 20 mA for measured signals


Data Storage

Extract via USB 2.0


Power

110 to 240 VAC. 48 to 63 Hz


Options

Optional RS422/RS485


Method

Meets ASTM D4519-16 for degassing method


OPERATING CONDITIONS


Sample Temperature

32 – 140° F (0 – 60 °C)


Ambient Temperature

32 – 131° F (0 – 55 °C)


Sample Flow Rate

031 – .044 GPM (7-10L/h)


Pressure

Maximum of 145 psig (10 bar)


Sample Medium

Liquid


MECHANICAL


Construction

Transmitter – high strength ABS. IP67
Wet Section – stainless steel or PVC


Dimensions

29 x 37 x 10″ (613 x 939 x 254mm)


Mounting

Wall mount or panel mount


Finish

Corrosion resistant