9096 Degas Cation Conductivity Analyzer

9096 Degas Cation Conductivity Analyzer

Range: 0-9.999µS/cm

Range: 0-99.9µS/cm


The Waltron 9096 Degas Cation Conductivity Analyzer accurately measures specific, cation, and degassed cation conductivity (as well as calculated pH) in ultrapure water applications. The patented dynamic degassing module brings industry-leading degassing efficiency with actionable results in less than 90 seconds. An enhanced color touchscreen user interface makes the 9096 easy and intuitive to operate and configure, and ready-to-use consumables simplify maintenance tasks. This combination measurement technology brings the highest degassing efficiencies available on the market, delivers the most accurate measurements, and ensures 100% confidence in reducing turbine start-up times. This instrument uses ambient air forced against the flow of the water sample to achieve its high degassing efficiency, resulting in significantly faster indications than any other comparable systems available. The cost savings on each start-up cycle between the Waltron dynamic system and the fastest reboiler system are significant based on even the most conservative assumptions. Additional benefits are better energy efficiency and reduced emissions of heat and exhaust.

  • Heatless dynamic degassing technology

  • Industry-leading degassing efficiency

  • Sample temperature fluctuation does not affect accuracy

  • No gas emissions or volatile acids

  • One transmitter for three conductivity values and pH

  • Alarms for resin exhaustion and low degassing efficiency

  • Easy to replace cation resin bottle

  • Easy to mount stainless steel panel

  • Significantly reduced turbine start-up times

PERFORMANCE


Range

0-10µS/cm, 0-100µS/cm


Accuracy

< 0.6% of the measuring range


Reagent Consumption (approximate)

Cation Resin (pre-rinsed) and Soda Lime; replace cartridges every two months


Sensor Classification

Cationic exchange and conductivity sensors


Degassing Efficiency

93.5%


Data Storage

Extract via USB 2.0


Power Supply

AC 110 to 240 V +10 / -15%; 48 to 63 Hz or AC/DC 20 to 30 V; 48 t0 63 Hz


OPERATING CONDITIONS


Sample Temperature Range

32 – 122° F (0 – 50 °C)


Ambient Temperature Range

32 – 140° F (0 – 60 °C)


Inlet Sample Flowrate

.031 – .044 GPM (7-10L/h), 6mm Swagelok


Inlet Sample Pressure

Maximum of 145 psig (10 bar)


Outlet Sample

Atmospheric


SIGNAL OUTPUTS


Analog Outputs

5 x 0/4 – 20 mA for measured signals


Alarms

General Alarm, Low Degassing Efficiency Alarm, Resin Exhausted Alarm


Optional

RS422/RS485


MECHANICAL


Construction

Transmitter – high strength ABS, IP67

Wet section – stainless steel or PVC


Dimensions

29 x 37 x 10″ (613 x 939 x 254mm)


Mounting

Wall mount or Panel mount


Finish

Corrosion resistant

Technical Documents